Federal / Material bans
SNAP program bans on HCFC foam blowing agents
40 CFR 82.174(d); 40 CFR Part 82 Subpart G, Appendices M, Q and U
In effect Regulation Effective 2015-09-18
Summary
No one may use a substitute for an ozone-depleting substance after EPA lists it as unacceptable. EPA lists HCFC-141b, HCFC-22, HCFC-142b and blends of them as unacceptable blowing agents in all foam end-uses, effective September 18, 2015, with exceptions for space, nuclear, defense and some research uses. Closed cell foam products made with these agents on or before December 1, 2017 may still be used. The same appendices list certain HFC blowing agents as unacceptable in named foam end-uses; HFC limits for foam are now set by the AIM Act rule at 40 CFR 84.54.
We checked this summary against the source document. The source controls.
What It Means for a Cold Chain Shipper
The duty falls on companies that blow foam, including makers of polystyrene and polyurethane coolers and liners. A shipper that buys finished coolers does not use a blowing agent and has no duty under these listings.
Parts of a Prescription Shipper
-
Vial Primary container Covered by this rule
-
Gel packs Refrigerant Covered by this rule
-
Foam cooler Insulation Covered by this rule
-
Outer carton Corrugated box Covered by this rule
The drawing is our reading of this rule and its drug exemption, for a prescription shipped in a foam cooler inside a corrugated carton. The text of the rule decides.
Drug Packaging
No exemption for drugs.
Dates
| 2015-09-18 | HCFC-141b, HCFC-22, HCFC-142b and blends listed as unacceptable in all foam blowing end-uses (Appendix U) |
| 2017-12-01 | Closed cell foam products made with these HCFCs on or before this date may still be used |
Sources
-
40 CFR Part 82 Subpart G (eCFR, current)
Primary source, eCFR, Office of the Federal Register