Federal Rules
United States statutes, regulations and bills in Congress that apply to a temperature-controlled parcel in every state.
There is no federal packaging fee or producer responsibility program. No federal rule sets a shipping temperature or a packaging standard for a pharmacy that mails a prescription to a patient; those duties come from state boards of pharmacy. Federal law does govern dry ice by air, what may be mailed, and what foam and other packaging may contain.
Last researched on 2026-11-26.
Packaging Fees
No federal packaging fee. The records below are EPA's one-time PFAS reporting rule and its proposed amendment. They are reporting duties, filed here because the site groups fees and reporting together.
-
Anyone who made or imported a PFAS for commercial purposes in any year from 2011 through 2022 must file a one-time report with EPA on uses, volumes, byproducts, exposure, disposal and health effects. The rule covers PFAS in mixtures and in articles, so a company that imported packaging containing PFAS in those years must report under the current text. Article importers may use a streamlined form. Filing opens on January 31, 2027, or 60 days after a date EPA will set in a later rule, whichever is earlier. Most reporters then have six months. Small manufacturers that report only as article importers have twelve. The only exemptions in force cover imported municipal solid waste sent for disposal and federal agencies importing for no commercial purpose.
Effect on packaging: Fees and reporting
Pharmacy shipments: The drug is exempt, its packaging is not
-
US Federal
Proposed exemptions to the TSCA PFAS reporting rule for imported articles and de minimis concentrations
90 FR 50923 (Nov. 13, 2025), proposed amendments to 40 CFR 705.12
EPA proposed to drop the PFAS reporting duty for anyone who imported a PFAS as part of an article, and for PFAS in a mixture or article below 0.1 percent. It also proposed exemptions for byproducts, impurities, non-isolated intermediates and small research quantities, and a three-month submission period. Comments closed December 29, 2025. In April 2026 EPA said it expects to issue the final rule before January 31, 2027.
Effect on packaging: Fees and reporting
Pharmacy shipments: The drug is exempt, its packaging is not
Proposed rule Source
Material Bans
-
US Federal
HFC blowing agent restrictions on foam products under the AIM Act Technology Transitions rule
40 CFR 84.54(a)(14) and (b)
Since January 1, 2025, no one may make or import foam products in the listed subsectors that use an HFC, or a blend containing one, with a global warming potential of 150 or more. From January 1, 2028, no one may sell, distribute or export those products, or buy or receive them for sale or distribution. The listed subsectors are rigid polyurethane appliance foam, commercial refrigeration foam, laminated boardstock, marine flotation foam, sandwich panels and slabstock; flexible polyurethane; integral skin polyurethane; extruded polystyrene boardstock, billet and extruded sheet; phenolic insulation board and bunstock; polyisocyanurate laminated boardstock; polyolefin; and rigid polyurethane spray foam. Foam for space and military uses has a January 1, 2026 date. Products must carry the label described in 40 CFR 84.58.
Effect on packaging: Limits chemicals
Pharmacy shipments: No exemption for drugs
-
US Federal
Clean Air Act ban on selling plastic foam products made with CFCs or HCFCs
42 U.S.C. 7671i(b), (d); 40 CFR 82.64, 82.66(c), 82.70(c)
No one may sell or distribute in interstate commerce a plastic foam product that contains or was made with a CFC, or one that contains or was made with an HCFC. Foam insulation products are exempt from the HCFC ban but not from the CFC ban. EPA defines them as products containing or consisting of closed cell rigid polyurethane foam, closed cell rigid polystyrene boardstock foam, closed cell rigid phenolic foam, or closed cell rigid polyethylene foam shaped to insulate pipes. HCFC foam products made and placed in inventory by December 31, 1993 may still be sold.
Effect on packaging: Limits chemicals
Pharmacy shipments: No exemption for drugs
-
Anyone who intends to make, import or process long-chain perfluoroalkyl carboxylate chemicals, or PFOA and its salts, must notify EPA before starting. The rule treats nearly any manufacture, import or processing of these chemicals as a significant new use, with listed exceptions such as semiconductor uses. Importing a chemical inside an article normally needs no notice. That exemption does not apply when PFOA, its salts or a chemical in the rule's Table 1 is part of a surface coating on the imported article. Importing fluoropolymers containing PFOA as part of articles is not a significant new use.
Effect on packaging: Limits chemicals
Pharmacy shipments: The drug is exempt, its packaging is not
-
The Guides state how the FTC reads environmental claims under the FTC Act ban on deceptive practices. A package may be called recyclable without qualification only when recycling facilities are available to at least 60 percent of consumers or communities where it is sold. A compostable claim needs scientific evidence that all the materials break down into usable compost in a safe and timely manner. An unqualified degradable claim is deceptive for an item headed for the solid waste stream that does not fully decompose within one year after customary disposal. The FTC opened a review in December 2022 and has not issued revised Guides.
Pharmacy shipments: Does not apply to shipping packaging
-
US Federal
Child-resistant packaging for oral prescription drugs under the Poison Prevention Packaging Act
16 CFR 1700.14(a)(10); 15 U.S.C. 1471-1476
Oral prescription drugs for human use must be dispensed in child-resistant packaging that meets 16 CFR 1700.15(a), (b) and (c), with listed exceptions such as sublingual nitroglycerin and cyclically taken oral contraceptives in mnemonic dispenser packs. The rule governs the drug's own container, the vial or bottle the patient opens. It says nothing about the shipping box, cooler or refrigerant.
Pharmacy shipments: Does not apply to shipping packaging
In effect Source -
US Federal
SNAP program bans on HCFC foam blowing agents
40 CFR 82.174(d); 40 CFR Part 82 Subpart G, Appendices M, Q and U
No one may use a substitute for an ozone-depleting substance after EPA lists it as unacceptable. EPA lists HCFC-141b, HCFC-22, HCFC-142b and blends of them as unacceptable blowing agents in all foam end-uses, effective September 18, 2015, with exceptions for space, nuclear, defense and some research uses. Closed cell foam products made with these agents on or before December 1, 2017 may still be used. The same appendices list certain HFC blowing agents as unacceptable in named foam end-uses; HFC limits for foam are now set by the AIM Act rule at 40 CFR 84.54.
Effect on packaging: Limits chemicals
Pharmacy shipments: No exemption for drugs
-
No one may make or process decaBDE, or products or articles containing it, after March 8, 2021, or distribute them in commerce after January 6, 2022, except for listed uses. Articles with less than 0.1 percent decaBDE by weight are outside the rule if the decaBDE was not added on purpose. Plastic shipping pallets made with decaBDE before March 8, 2021 may be distributed until the end of their service life. Plastic recycled from decaBDE articles may be reused if no new decaBDE is added. Anyone who makes, processes or distributes decaBDE or articles containing it must keep business records for five years showing compliance.
Effect on packaging: Limits chemicals
Pharmacy shipments: The drug is exempt, its packaging is not
In effect Source -
US Federal
Farewell to Foam Act: federal ban on selling EPS foam coolers, loose fill and food service ware from 2028
S. 897 / H.R. 1918, 119th Congress (2025-2026)
Would bar manufacturers, distributors and retailers from selling, offering for sale or distributing expanded polystyrene (EPS) coolers and EPS loose fill (packing peanuts) in the United States from January 1, 2028. Food service providers, manufacturers, distributors and retailers would also have to stop selling, offering or distributing single-use EPS food service ware on that date. An EPS cooler is a portable container made entirely or partly of EPS and designed or intended for cold storage. Portable containers intended for drugs, medical devices or biological products are excluded from that definition; loose fill has no such exclusion. EPA would enforce the ban: a written notice for a first violation, then civil penalties of $250 for a second, $500 for a third and $1,000 for each later violation. Food service providers and retailers with under $1 million in annual revenue, and manufacturers and distributors with under $5 million, could be fined no more than once in any 7-day period. EPA could let a state enforce the ban.
Effect on packaging: Restricts a material
Pharmacy shipments: Unsettled
-
US Federal
PACK Act: federal standard for recyclable, compostable and reusable claims on consumer product packaging
H.R. 6832, 119th Congress (2025-2026)
As introduced, would add a new section 27 to the Federal Trade Commission Act. No one could call packaging for a consumer product recyclable, compostable or reusable unless it is. A recyclable claim would have to say how widely recycling is available, unless programs reach at least 60 percent of consumers or communities where the product is sold and the whole package, minus minor incidental parts, is recyclable. A compostable claim would need competent and reliable scientific evidence, and an unqualified reusable claim would need a collection and reuse system or a product sold for reusing the package. Every claim would need certification by an accredited third-party body. Packaging that cannot carry a claim could not show a resin code inside chasing arrows; it could show the code inside an equilateral triangle under ASTM D7611. The FTC would issue guidance within two years and could not write binding rules. States could not keep or enforce any requirement that is not identical to this section.
Pharmacy shipments: Does not apply to shipping packaging
Pending bill Source -
US Federal
Truth in Labeling Act: national standards for recyclable, compostable, reusable and refillable labels on packaging
S. 5302 / H.R. 10048, 119th Congress (2025-2026)
Would have EPA, working with the FTC, set standardized on-package labels within two years of enactment for packaging, food service products and beverage containers that claim to be recyclable, compostable, reusable or refillable. A label making such a claim would have to follow that standard and meet the bill's criteria for each claim. Material that meets none of the criteria could not carry a chasing arrows symbol or any marking that tells consumers to recycle, compost, reuse or refill it. Every plastic covered material sold, distributed or imported into the U.S. would have to carry a resin identification code, and the code could not sit inside chasing arrows unless the material qualifies as recyclable and no other placement is physically feasible. Two years after the labels are set, selling or distributing covered material that breaks these rules would be a deceptive practice under the FTC Act. Material made within 18 months after the labels are published is exempt. The FTC would give 180 days to correct a violation before fines. States keep their own laws except on resin code placement.
Pharmacy shipments: Does not apply to shipping packaging
Pending bill Source -
US Federal
Forever Chemical Regulation and Accountability Act: nationwide phaseout of nonessential PFAS uses
H.R. 8016 / S. 4153, 119th Congress (2025-2026)
Would require every manufacturer and user of PFAS to end all nonessential uses within 10 years of enactment and to file a phaseout plan with EPA within 3 years. A use is essential only if EPA designates it, on National Academies advice, as critical for health, safety or the functioning of society, necessary for the item to work, and without a safer alternative. One year after enactment, no one could sell, offer for sale or distribute for sale in interstate commerce food packaging and containers that contain PFAS, along with carpets, fabric treatments, juvenile products and oil or gas products. EPA would set annual PFAS use and release reporting by rule within 3 years. Ten years after enactment, manufacturers and users could not release PFAS above the detection threshold of an EPA-validated method. Violations would carry civil penalties, and reckless violations up to 5 years in prison. States could set stricter rules but not weaker ones.
Effect on packaging: Limits chemicals
Pharmacy shipments: No exemption for drugs
Pending bill Source
Pharmacy Delivery
-
US Federal
Wholesale distributor inspection of incoming and outgoing drug shipments
21 CFR 205.50(d) and (e)(3)
Part 205 sets the minimum terms that every state license for a prescription drug wholesale distributor must contain. On receipt, each outside shipping container must be visually examined for identity and for damage that suggests the contents may be contaminated or unfit. Each outgoing shipment must be inspected for identity and to make sure no drug that was damaged in storage or held under improper conditions is delivered. When a drug is returned, the distributor must consider how it was held, stored or shipped before and during the return and the condition of its container, carton and labeling. If those conditions cast doubt on the drug's safety, identity, strength, quality or purity, the distributor must destroy it or return it to the supplier unless examination or testing shows it meets standards. Incoming and outgoing drugs fall under the recordkeeping rules in paragraph (f).
In effect Source -
US Federal
Product identifier on every package and homogeneous case (DSCSA)
21 U.S.C. 360eee-1(a)(9), (b)(2) and (e)(2) (FD&C Act sec. 582)
A manufacturer must affix or imprint a product identifier on each package and each homogeneous case of a prescription drug it intends to introduce in a transaction, and keep the identifier information for at least 6 years after the transaction. A repackager that repacks and relabels product for further sale has the same duty. A package is the smallest individual saleable unit intended for sale to a dispenser. A homogeneous case is a sealed case containing only product with a single National Drug Code from a single lot. Unless FDA allows other technology through guidance, the data goes in a 2-dimensional data matrix barcode on a package and in a linear or 2-dimensional data matrix barcode on a homogeneous case. The identifier shows the standardized numerical identifier (the NDC plus a serial number of up to 20 characters), the lot number and the expiration date, in human-readable form and on a machine-readable carrier.
-
A manufacturer or authorized distributor of record may send a prescription drug sample by mail or common carrier only to a practitioner licensed to prescribe it, or, at a licensed practitioner's written request, to the pharmacy of a hospital or other health care entity. Before delivery it must have the practitioner's signed written request and must verify with the state authority that the practitioner may prescribe the drug. On delivery the recipient signs a receipt, which goes back to the sender. The receipt names the person who acknowledged delivery and gives the drug name and strength, the quantity delivered and the delivery date. Section 203.34 requires written procedures for distributing samples by mail or carrier, including how requests are reconciled with receipts. Section 203.32 requires manufacturers and distributors to store and handle samples so they keep their stability, integrity and effectiveness, and says following the compendial and labeling storage requirements generally satisfies it.
-
A hospital, health care entity or charitable institution that returns a prescription drug to the manufacturer or wholesale distributor it came from must keep the drug under proper conditions for storage, handling and shipping. It must give the receiver written documentation that those conditions were maintained. It must also fill out a credit memo naming the institution, the supplier, the product, lot number, quantity and return date, send a copy to the manufacturer and keep a copy. A return that meets these terms is exempt from the federal ban on reselling drugs bought by a hospital or health care entity.
-
US Federal
Donated drug samples: delivery by mail or carrier in a sealed carton
21 CFR 203.39(a) and (b)
A licensed practitioner or charitable institution that donates a drug sample to a charitable institution must deliver it by mail or common carrier, by collection by the recipient's authorized agent or employee, or by personal delivery. The donor must place the samples in a sealed carton. The samples must arrive in their original unopened packaging with labeling intact. Before any is dispensed, a licensed practitioner or registered pharmacist at the recipient must examine the samples against the donation record and check them for signs of adulteration, including evidence that a sample was stored or shipped under conditions that might affect its stability, integrity or effectiveness.
-
US Federal
Biologics: required temperatures during shipment
21 CFR 600.15
The listed biological products must be kept at set temperatures during shipment. Live measles, mumps and rubella vaccines, alone or combined, and Measles Live and Smallpox Vaccine: 10 °C or colder. Live oral poliovirus vaccines, liquid smallpox vaccine and yellow fever vaccine: 0 °C or colder. Cryoprecipitated AHF, fresh frozen plasma and plasma: -18 °C or colder. Frozen red blood cells: -65 °C or colder. Source plasma: -5 °C or colder. Liquid source plasma: 10 °C or colder. Liquid plasma and liquid red blood cells: 1 to 10 °C. Platelets and platelet rich plasma: 1 to 10 °C if the label says to store them at 1 to 6 °C, or as close as reasonably possible to 20 to 24 °C if the label says 20 to 24 °C. Whole blood shipped from a storage facility: 1 to 10 °C; whole blood going from collection to processing has its own conditions. Any exemption or change needs written approval from the director of FDA's Center for Biologics Evaluation and Research, as a supplement to the biologics license application.
In effect Source -
US Federal
Medicare Part D: home infusion drugs delivered within 24 hours of hospital discharge
42 CFR 423.120(a)(4)
A Medicare Part D plan's pharmacy network must give enrollees adequate access to home infusion pharmacies. The plan must make sure each network home infusion pharmacy can deliver home-infused drugs in a form that can be given in a clinically appropriate way, can supply infusible drugs for both short-term acute and long-term chronic therapy, has the professional services and ancillary supplies for home infusion in place before it dispenses, and delivers home infusion drugs within 24 hours of discharge from an acute care setting, or later if so prescribed.
In effect Source -
An establishment that makes human cells, tissues, or cellular or tissue-based products (HCT/Ps) must use packaging and shipping containers designed and built to protect each HCT/P from contamination. For each type of HCT/P it must set the shipping conditions to be kept during transit. It must have written procedures for this and document each activity, including the HCT/P, the date, the quantity and the disposition, such as who received it. An HCT/P shipped within or between establishments before it is released for distribution must travel in quarantine. These are core current good tissue practice requirements; an establishment that performs only some steps follows the ones that apply to it.
-
US Federal
Proposed national standard: wholesale distributors must transport drugs without exposure and report excursions within 24 hours
Proposed 21 CFR 205.26(c)(3) and (c)(4), 87 FR 6708 (Feb. 4, 2022), RIN 0910-AH11
FDA proposed national standards for licensing prescription drug wholesale distributors. Under the proposal a distributor must ship drugs in a way that protects against breakage, contamination, adulteration and theft and prevents exposure to conditions that could harm identity, strength, quality or purity. Any deviation from storage requirements during transport must be identified, investigated, documented, corrected and reported no later than 24 hours after discovery to the trading partner the drug came from and to the manufacturer. Every incoming shipping container must be examined for identity and for damage or alteration, and every outgoing shipment inspected so that no damaged drug, or one held under improper conditions, is shipped. A distributor that uses a contractor stays responsible for compliance. The proposal says the standards would take effect 2 years after the final rule is published.
Proposed rule Source -
US Federal
Proposed national standard: third-party logistics providers must ship drugs at labeled conditions and stay responsible for carriers
Proposed 21 CFR 205.12(c)(1), (c)(5) and (c)(6), 87 FR 6708 (Feb. 4, 2022), RIN 0910-AH11
FDA proposed national licensing standards for third-party logistics providers (3PLs) that store and ship drugs for manufacturers and other trading partners. A 3PL would need written procedures for transport under which products are protected against breakage, contamination, adulteration and theft and kept from conditions that could compromise their quality and integrity. Deviations from storage requirements during transport must be promptly identified, investigated, documented and reported to the trading partner that sent the product and to the manufacturer. A 3PL that hands shipments to a common carrier or other transportation provider stays responsible for compliance while the products are in transit, and the arrangement must be documented. Products must be distributed at the temperatures and conditions in their labeling. Each incoming shipping container must be examined on receipt and each outgoing shipment inspected. Under the statute the 3PL standards take effect 1 year after the final rule is published; FDA said it does not intend to enforce the licensing requirements until 2 years after publication.
Proposed rule Source
Transport
-
A package of dry ice going by aircraft or vessel must let carbon dioxide gas escape so pressure cannot build up and burst it. It must meet the general packaging rules in 49 CFR Part 173 Subpart B, but it does not need a UN specification (Part 178) package. By air, the shipper must mark the net mass of dry ice on the outside, make arrangements with the airline for each shipment, and supply either shipping papers or alternative written documentation giving the name (Dry ice or Carbon dioxide, solid), class 9, UN1845, the number of packages and the net quantity of dry ice in each. A package with 2.5 kg (5.5 lb) of dry ice or less, used to cool the contents, is excepted from all other hazmat requirements if it is vented and marked "Dry ice" or "Carbon dioxide, solid", with the name of the contents being cooled and the net weight of the dry ice (or a statement that it is 2.5 kg or less). Dry ice cooling material shipped for diagnostic or treatment purposes is excepted from the shipping paper and certification requirements if the package is vented, the airline arrangement is made, and the package is marked as dry ice and as being for diagnostic or treatment purposes.
In effect Source -
US Federal
Hazardous materials table entry for dry ice, UN1845: air and vessel only, 200 kg per package by air
49 CFR 172.101, Hazardous Materials Table, entry "Carbon dioxide, solid or Dry ice"
The table lists "Carbon dioxide, solid or Dry ice" as Class 9, UN1845, with packaging rules in 49 CFR 173.217 and a limit of 200 kg per package on both passenger and cargo aircraft. The entry carries the symbols A and W. Under 172.101(b), A means the material is regulated only when offered or intended for transport by aircraft, and W only when by vessel, unless it is a hazardous substance or hazardous waste. Dry ice moving only by truck or rail is therefore not subject to the federal hazmat rules.
In effect Source -
US Federal
Dry ice carried by an airline passenger or crewmember
49 CFR 175.10(a)(10)
With the airline's approval, a passenger or crewmember may carry up to 2.5 kg (5.5 lb) of dry ice per person to pack perishables that are not themselves hazardous materials. The package must let carbon dioxide gas escape. If it goes in checked baggage, it must be marked "DRY ICE" or "CARBON DIOXIDE, SOLID" and marked with the net weight of the dry ice or a statement that it is 2.5 kg or less.
In effect Source -
US Federal
Liquid nitrogen dry shippers and other cryogenic liquid refrigerants
49 CFR 172.102 special provisions 345 and 346; 49 CFR 173.320; 49 CFR 175.10(a)(24)
Refrigerated liquid nitrogen (UN1977, Division 2.2) is a regulated hazardous material in every mode. Special provision 346 removes it from all other hazmat requirements when it travels under the rules for open cryogenic receptacles in 49 CFR 173.320, the nitrogen is fully absorbed in a porous material, and the receptacle holds no other hazardous material (a dry shipper). Special provision 345 removes from the hazmat rules open glass double-walled, vacuum-insulated receptacles of 1 L or less, each packed in an outer packaging with enough cushioning and absorbent to protect it. Under 173.320(a), cryogenic atmospheric gases in insulated packagings built so pressure stays at or below 25.3 psig are excepted when moved by motor vehicle or rail, except that incident reporting, Part 172 subparts A, B, C, D, G and H (which cover shipping papers, marking, emergency response information and training) and Part 173 subparts A and B still apply. For aircraft, 173.320(c) points to ICAO Technical Instructions Packing Instruction 202. A passenger may carry an insulated package of refrigerated liquid nitrogen in checked or carry-on baggage under 175.10(a)(24) if it meets ICAO Packing Instruction 202, the ICAO packaging specifications and special provision A152.
In effect Source -
A Category B infectious substance ("Biological substance, Category B", UN3373) must go in a triple packaging: a primary receptacle, a secondary packaging, and a rigid outer packaging. The package must pass a 1.2 m drop test and hold up under the temperature, humidity and pressure changes of transport. The outer packaging must show the UN3373 diamond mark and the words "Biological substances, Category B", and a name and monitored phone number of a knowledgeable person must appear on the package or a document such as the air waybill. For liquids, the primary and secondary packagings must be leakproof with absorbent between them. By air, the primary or secondary packaging must withstand a 95 kPa pressure differential, with limits of 1 L per primary receptacle and 4 L (or 4 kg for solids) per outer package; ice, dry ice and liquid nitrogen do not count toward these limits. Ice or dry ice must go outside the secondary packaging or in an overpack, with supports to hold the secondary in place; ice needs a leakproof outer packaging or liner, and dry ice needs a vented outer packaging that meets 173.217. A package with dry ice must be marked "Dry ice" or "Carbon dioxide, solid" with an indication that the material is for diagnostic or treatment purposes. Packaging makers must give filling and closing instructions, and the shipper must follow them. Each person who offers or transports these packages must know the section's requirements.
In effect Source -
Several materials are not regulated as Division 6.2 infectious substances. These include a biological product (including an experimental or investigational one) subject to federal approval, permit, review or licensing, such as FDA requirements; blood and blood products, plasma derivatives, and human cells and tissues regulated under the Public Health Service Act or the Food, Drug, and Cosmetic Act; dried blood spots; human or animal samples sent for routine testing not related to diagnosing an infectious disease (drug testing, cholesterol, glucose, kidney or liver function, pregnancy, cancer biopsies) when the sample is unlikely to be infectious; and patient samples or biological products moved by a private or contract carrier in a vehicle used only for such materials, other than Category A.
In effect Source -
Except by aircraft, a lithium battery or fuel cell inside a data logger or cargo tracking device attached to or placed in a package is not subject to the hazmat rules if the device is in use or intended for use during transport, the battery meets the applicable construction and test rules, and the device can withstand normal transport shocks and loads and is safe in the environments it may meet. By aircraft, the current section gives only a narrow exception: a logger in a package of COVID-19 pharmaceuticals is excused from the lithium battery mark and documentation in 173.185(c)(3) and (c)(4)(iv), and so is the same package returned empty for reuse if arranged with the airline. The exception does not cover batteries or devices shipped as cargo.
-
US Federal
Small lithium cells and batteries in equipment, such as temperature loggers, shipped in a package
49 CFR 173.185(a) and (c)
Every lithium cell or battery must be of a type that passed the UN Manual of Tests and Criteria, Part III, sub-section 38.3. A package of small cells or batteries (up to 20 Wh per lithium ion cell or 100 Wh per battery; up to 1 g lithium per lithium metal cell or 2 g per battery), including ones contained in equipment, is excepted from Part 172 subparts C through H (shipping papers, marking, labeling, placarding, emergency response information and training) and from UN performance packaging, except where paragraph (c) says otherwise. The equipment must protect the battery or the battery must be in an inner packaging inside a strong rigid outer package. The package must show the lithium battery mark (UN3481 for lithium ion, UN3091 for lithium metal, contained in equipment), except when it holds only button cells in equipment, or when the consignment is two packages or fewer each holding no more than four cells or two batteries in equipment. By air, a package may hold only the number of batteries needed to run the equipment plus two spare sets, up to 5 kg of batteries; the air waybill must note compliance when the mark is required; and each person who prepares the package must be instructed on these conditions. The lithium battery mark design in effect on May 9, 2024 may be used until December 31, 2026.
In effect Source -
US Federal
Hazmat training for staff who prepare dry ice or battery shipments
49 CFR Part 172, Subpart H (172.700-172.704)
A hazmat employer must train and test each hazmat employee on the hazmat rules that apply to that person's job. An employee may not do a regulated task until instructed in it, except that a new employee may work under direct supervision of a trained employee for up to 90 days. Training must be repeated at least every three years. The employer must keep a record of each employee's current training covering the past three years, for as long as the person is employed in the role and 90 days after, and show it to DOT on request. The employer is responsible for compliance whether or not training is finished.
In effect Source -
US Federal
Mailing dry ice by USPS: air and surface limits, marking and documentation
USPS Publication 52, sections 349.3 and 349.6, and Appendix C, Packaging Instruction 9A
Dry ice may be mailed only within the United States, and only as a refrigerant for mailable contents; it is prohibited in international mail. Packages must let carbon dioxide gas escape and meet 49 CFR 173.217 and 175.10(a)(10). A fiberboard box needs enough insulation to stop condensation from wetting the carton. By air, each mailpiece may hold no more than 5 pounds of dry ice, must carry a Class 9 hazard label, must be marked "Dry Ice, UN1845" (or "Carbon Dioxide Solid, UN1845"), and must have a Shipper's Declaration for Dangerous Goods in triplicate attached outside. By surface, a mailpiece may hold more than 5 pounds, must be marked "Surface Only" or "Surface Mail Only" and "Dry Ice, UN1845", and needs no declaration or Class 9 label. Every dry ice mailpiece must be marked on the address side with the name of the contents being cooled and the net weight of the dry ice. A mailpiece prepared for surface must never be routed by air.
In effect Source -
US Federal
Mailing prescription drugs and controlled substances by USPS
USPS Publication 52, section 453 (Controlled Substances and Drugs)
Only pharmacists, medical practitioners or other authorized dispensers may mail non-controlled prescription medicines, and only to patients under their care. Controlled substances may be mailed domestically only when both sender and addressee are registered with the DEA or exempt from registration, through an authorized mail-back program, or as prescription medicines mailed by manufacturers or their registered agents, pharmacies, practitioners or other authorized dispensers as federal rules allow. Poisonous drugs and medicines may be mailed only from manufacturers or dealers to licensed professionals such as physicians, dentists, pharmacists and veterinarians. All mailable drugs need secure packaging that keeps them from damage or shifting in transit. For controlled substances, the inner package must be marked and sealed as the Controlled Substances Act rules require and labeled with the prescription number and the name and address of the dispensing pharmacy or practitioner; it must sit inside a plain outer wrapper or box with no markings showing the contents; and the general packaging rules in DMM 601.1 to 601.7 apply. Non-controlled drugs must also go in a plain outer wrapper, except promotional samples of over-the-counter drugs. The mailer is responsible for following federal, state and local laws, such as the Poison Prevention Packaging Act and the Consumer Product Safety Act. Prescription drugs being returned for a recall, a manufacturer withdrawal or a dispensing error may be sent to the manufacturer or its registered agent by Priority Mail Return service.
In effect Source -
Poisons, explosives, hazardous materials, flammable materials, disease germs and any other article that may kill or injure a person or damage the mail or other property are nonmailable. The Postal Service may allow such articles in the mail under its own rules on preparation and packing when they are not outwardly or of their own force dangerous. It may limit mailing of poisonous drugs and medicines to shipments from the manufacturer or a dealer to licensed physicians, surgeons, dentists, pharmacists, druggists, cosmetologists, barbers and veterinarians. Knowingly mailing nonmailable matter other than under the Postal Service's rules is punishable by a fine and up to one year in prison. Doing so with intent to kill or injure someone, or to damage the mail or other property, is punishable by up to twenty years, and by death or life imprisonment if a death results.
In effect Source -
US Federal
DEA security duties when shipping controlled substances by carrier
21 CFR 1301.74(e); 21 CFR 1301.76(c) and (d)
A DEA registrant that ships controlled substances must choose common or contract carriers that provide adequate security against in-transit loss, and must take precautions such as making sure shipping containers do not show that the contents are controlled substances. The duty is in the rules for non-practitioners, but a practitioner (including a pharmacy) must meet it whenever it distributes controlled substances without a distributor registration. Central fill pharmacies must meet it when choosing carriers to move filled prescriptions to a retail pharmacy, and must report in-transit losses on DEA Form 106; a retail pharmacy that arranges the pickup carries the same duties. Any registrant must report a theft or significant loss to the DEA field office in writing within one business day of discovery and file DEA Form 106 within 45 days.
In effect Source -
US Federal
USPS packaging and marking rules for mailed liquids
USPS Domestic Mail Manual 601.3.4; Publication 52, section 451
A mailpiece holding a liquid must be marked on the outer container to show it contains liquid and must carry orientation arrows under Publication 52 section 223. Liquid containers must close with screw caps of at least one and a half turns, soldering, clips or similar; friction-top lids alone are not acceptable. Breakable containers (glass, plastic, porcelain) and pull-tab or friction-top metal containers over 4 fluid ounces must be triple-packaged: absorbent material enough to soak up all the liquid, a sealed leakproof secondary container such as a plastic bag, and a strong sealed outer container. Containers certified to ISTA Test Procedure 3A may be used instead, with test results provided on request. Publication 52 defines a liquid, for mailability, to include a nonhazardous substance that may liquefy under existing conditions.
-
US Federal
Airline handling of dry ice carried as cargo
49 CFR 175.900
An airline may carry dry ice, alone or as a refrigerant for other goods, only after it has made suitable arrangements based on the aircraft type, its ventilation rates, how the dry ice is packed and stowed, whether animals are on the same flight, and other factors. The airline must tell its ground staff that dry ice is being loaded or is on board. If the airline adds dry ice to a unit load device prepared by one shipper, it must update the information given to the pilot in command and the marking on the unit load device to show the new quantity.
In effect Source -
US Federal
Mailing biological products, Category B specimens and exempt specimens by USPS
USPS Publication 52, section 346.3 (346.31, 346.321, 346.325, 346.326, 346.327)
Infectious substances may go in domestic mail only when intended for medical or veterinary use, research, or laboratory certification related to public health, and Category A substances are nonmailable. A Category B substance (UN3373) must be triple-packaged under 49 CFR 173.199 and sent by Priority Mail or Priority Mail Express. The secondary packaging must carry the biohazard symbol, the address side must be marked "Biological Substance, Category B" and "UN3373", and the outer packaging must show the name and phone number of a person who knows the material. Each primary receptacle may hold up to 1 liter of liquid or 4 kg of solid, and the primary or secondary packaging must withstand a 95 kPa pressure differential from -40 to 55 degrees C. Biological products subject to FDA or USDA approval, blood products and human cell-based products regulated under the Public Health Service Act or the Food, Drug, and Cosmetic Act are not regulated as Division 6.2 materials but must be packaged under Packaging Instruction 6G: a sealed primary receptacle with absorbent and cushioning, a sealed leakproof secondary packaging, and the biohazard symbol on the primary receptacle or inner packaging. Above 50 ml of liquid per mailpiece, each primary receptacle and each secondary packaging is limited to 500 ml, and the secondary packaging must sit in a fiberboard box or equivalent outer packaging. Exempt human or animal specimens (routine testing) must be triple-packaged, limited to 500 ml or 500 g per secondary packaging, and marked "Exempt human specimen" or "Exempt animal specimen" on the address side. Shipping papers and outer content markings are not required for biological products or exempt specimens.
In effect Source -
US Federal
Proposed air exception for data loggers and cargo tracking devices (HM-215R)
91 FR 5996 (Feb. 10, 2026), Docket PHMSA-2023-0111 (HM-215R), RIN 2137-AF64, proposed 49 CFR 173.14(b)
PHMSA proposed to let data loggers and cargo tracking devices with installed lithium batteries, attached to or placed in packages, overpacks or unit load devices, travel by aircraft outside the hazmat rules. Conditions: the device is in use or intended for use during transport; each battery meets 173.185(a) and special provision 388; lithium ion cells or batteries are 20 Wh or less and lithium metal 1 g or less; no more devices than needed to track or record the consignment; the device withstands normal shocks and loads, cannot generate dangerous heat, and meets electromagnetic radiation standards so it does not interfere with aircraft systems. The COVID-19 pharmaceutical exception would move to paragraph (c), and PHMSA asked whether to keep it.
Proposed rule Source -
US Federal
Proposed extension of the device exception to sensors and sodium ion batteries (HM-215S)
91 FR 67720 (Oct. 27, 2026), Docket PHMSA-2025-0048 (HM-215S), RIN 2137-AF75, proposed 49 CFR 173.14
PHMSA's second 2026 harmonization proposal would rewrite 49 CFR 173.14 to cover sensors as well as data loggers and cargo tracking devices, to allow sodium ion batteries as well as lithium batteries and fuel cells, and to use the word "device" in place of "equipment". It repeats the air exception proposed in HM-215R, with the 20 Wh limit applied to lithium ion and sodium ion cells and batteries and the 1 g limit to lithium metal, and keeps the COVID-19 pharmaceutical marking exception in paragraph (c). The proposal would align the hazmat rules with the 2027-28 ICAO Technical Instructions, Amendment 43-26 to the IMDG Code and the 24th revised UN Model Regulations, and would adopt Addendum No. 1 to the 2025-26 ICAO Technical Instructions.
Proposed rule Source
Deadlines
Packaging fees Material bans Pharmacy delivery Transport
| Date | Change |
|---|---|
| 2026-12-31 | Last day to use the lithium battery mark design in effect on May 9, 2024 (49 CFR 173.185(c)(3)(ii)) Small lithium cells and batteries in equipment, such as temperature loggers, shipped in a package |
| 2027-01-31 | Latest date the submission period opens. It opens earlier, 60 days after a date EPA will set in a later rule, if that comes first. The period lasts six months, or twelve months for small manufacturers that report only as article importers. TSCA section 8(a)(7) one-time PFAS reporting, including PFAS imported in articles |
| 2028-01-01 | No sale, distribution or export of those foam products (three years after the manufacture date) HFC blowing agent restrictions on foam products under the AIM Act Technology Transitions rule |