Summary
A Category B infectious substance ("Biological substance, Category B", UN3373) must go in a triple packaging: a primary receptacle, a secondary packaging, and a rigid outer packaging. The package must pass a 1.2 m drop test and hold up under the temperature, humidity and pressure changes of transport. The outer packaging must show the UN3373 diamond mark and the words "Biological substances, Category B", and a name and monitored phone number of a knowledgeable person must appear on the package or a document such as the air waybill. For liquids, the primary and secondary packagings must be leakproof with absorbent between them. By air, the primary or secondary packaging must withstand a 95 kPa pressure differential, with limits of 1 L per primary receptacle and 4 L (or 4 kg for solids) per outer package; ice, dry ice and liquid nitrogen do not count toward these limits. Ice or dry ice must go outside the secondary packaging or in an overpack, with supports to hold the secondary in place; ice needs a leakproof outer packaging or liner, and dry ice needs a vented outer packaging that meets 173.217. A package with dry ice must be marked "Dry ice" or "Carbon dioxide, solid" with an indication that the material is for diagnostic or treatment purposes. Packaging makers must give filling and closing instructions, and the shipper must follow them. Each person who offers or transports these packages must know the section's requirements.
We checked this summary against the source document. The source controls.
What It Means for a Cold Chain Shipper
This applies when the parcel holds patient specimens that are Category B, for example a return lab kit, not when it holds a dispensed drug. For such specimens shipped on dry ice or ice, the refrigerant goes outside the secondary packaging, the secondary must be braced so it stays put as the refrigerant melts or sublimates, dry ice needs a vented outer box, and ice needs a leakproof outer packaging or liner.
Sources
-
49 CFR 173.199 Category B infectious substances (eCFR renderer API)
Primary source, National Archives, Office of the Federal Register (eCFR)
-
49 CFR 172.101 Hazardous materials table, entry Biological substance, Category B, UN3373
Primary source, National Archives, Office of the Federal Register (eCFR)